Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Volatile matter content determination is a key quality and environmental test for fireproof paints applied to building curtain walls, quantifying the fraction of the wet coating that evaporates during drying and curing. Accredited third-party laboratories perform this measurement in accordance with standards such as GB/T 1725, ISO 3251 and ASTM D2369 to verify VOC compliance, confirm solids content and safeguard the long-term fire-resistive performance of curtain wall fire protection systems. This article explains the applicable standards, sample types, test items, analytical methods and practical applications of volatile content testing for curtain wall fireproof coatings.

Technical Overview

Fireproof paints for curtain wall systems include intumescent coatings applied to steel mullions, transoms and back-up structures, cementitious spray-applied fire-resistive materials, and firestop coatings used at perimeter joints between the curtain wall and floor slabs. Because these coatings must simultaneously satisfy fire performance requirements under standards such as GB 14907, GB 8624 and ASTM E119, and environmental limits on volatile emissions under GB 30981, the determination of volatile matter content is a fundamental quality control test.

Volatile matter content is defined as the mass fraction of a coating sample lost when heated under specified, reproducible conditions. For curtain wall fireproof paints, this value directly influences the achievable dry film thickness per coat, drying time, theoretical spreading rate, on-site VOC emissions and the integrity of the intumescent char layer that provides fire resistance. An excessively high volatile content reduces the non-volatile solids and may prevent the coating from reaching the thickness required for the specified fire rating, while an abnormally low value can indicate over-thickening, solvent loss from storage or formulation deviation.

The principal standards governing this determination include:

  • GB/T 1725 and GB/T 6751: gravimetric determination of non-volatile matter and volatile matter of paints
  • ISO 3251: paints, varnishes and plastics, determination of non-volatile-matter content
  • ASTM D2369: standard test method for volatile content of coatings
  • GB/T 23986, ISO 11890-2 and ASTM D6886: gas chromatographic determination of VOC content in waterborne coatings
  • GB/T 6283, ISO 760 and ASTM D4017: determination of water content by Karl Fischer titration
  • GB/T 6750 and ISO 2811-1: determination of density by pycnometer, required for VOC calculation in g/L

Testing Samples

Water-Based Intumescent Fire-Retardant Coatings

Emulsion-binder intumescent coatings are the most common fireproof paints for visible curtain wall steelwork. They contain a substantial water fraction, so total volatile matter must be corrected for water content before the true VOC value is reported.

Solvent-Based Thin-Film Intumescent Coatings

These coatings use organic solvent carriers and are subject to strict VOC limits under GB 30981. Nearly all of their volatile fraction consists of regulated organic compounds, making gravimetric and chromatographic results closely correlated.

Thick-Film Cementitious and Spray-Applied Fire-Resistive Materials

Mineral-bonded, gypsum-based or portland-cement-based spray materials used behind curtain wall spandrels contain free water and limited organic volatiles. Volatile content testing verifies water balance, solids consistency and the absence of unauthorized organic additives.

Firestop and Perimeter Fire Barrier Coatings

Coatings and sealants applied at the gap between floor slabs and curtain wall panels, tested for fire resistance under references such as ASTM E2307 and EN 1364-4, are also evaluated for volatile content to confirm low emissions in occupied buildings.

Compatible Primers and Topcoats

Primers and weather-resistant topcoats used within curtain wall fire protection systems are tested to verify that their volatile fractions match technical data sheet declarations and project specifications.

Testing Items

Typical test items for a volatile content determination program include:

  • Volatile matter content, expressed as mass fraction in percent
  • Non-volatile matter content (solids content), expressed as mass fraction in percent
  • Water content, determined separately for waterborne products
  • VOC content, calculated and expressed in grams per liter
  • Density of the coating in g/mL, required for the VOC calculation
  • Specific regulated volatiles where required, including benzene, toluene, ethylbenzene, xylenes, formaldehyde and halogenated solvents
  • Assessment of results against limit values in GB 30981, GB 14907 and project specifications

Testing Methods

Gravimetric Oven Method

The reference method follows GB/T 1725, GB/T 6751, ISO 3251 and ASTM D2369. The sample is homogenized, and approximately one gram is weighed into a tared flat-bottomed dish and distributed evenly. The dish is heated in a ventilated oven at 105 ± 2 °C for one hour, or under the product-standard condition, then cooled to ambient temperature in a desiccator and reweighed. Heating cycles are repeated to constant mass. The volatile matter content is calculated as the mass loss divided by the original sample mass, multiplied by one hundred.

Karl Fischer Water Determination

For waterborne fireproof paints, the total mass loss includes both water and organic volatiles. Water content is measured by Karl Fischer titration according to GB/T 6283, ISO 760 or ASTM D4017, using direct injection or oven extraction, so that water can be subtracted when calculating the VOC content.

Gas Chromatographic Analysis

Individual volatile organic compounds in waterborne coatings are identified and quantified by gas chromatography with flame ionization detection according to GB/T 23986, ISO 11890-2 or ASTM D6886. An internal standard is used, and results confirm both compliance with specific-substance limits and the accuracy of the gravimetric VOC calculation.

Density Measurement and VOC Calculation

The density of the coating is measured with a pycnometer per GB/T 6750 or ISO 2811-1. The VOC content in g/L is then calculated by multiplying the difference between total volatile matter content and water content by the density and one thousand. This result is compared with the regulatory limits applicable to protective and fire-retardant coatings.

Applications

Test results are used throughout the life cycle of curtain wall fire protection:

  • Factory batch release and quality control during fireproof paint production
  • Incoming material inspection at curtain wall fabrication plants and construction sites
  • Verification of VOC declarations on technical data sheets and environmental product documentation
  • Compliance demonstration for green building certification and indoor air quality requirements
  • Support for fire-resistance assessments under GB 14907, GB 8624 and ASTM E119 by confirming solids content and film build capability
  • Failure analysis of coating defects such as slow drying, blistering, pinholes or insufficient intumescent expansion
  • Research and development support for low-VOC reformulation of intumescent systems

FAQ

What is the difference between volatile matter content and VOC content?

Volatile matter content is the total mass lost on heating, including water. VOC content excludes water and certain exempt compounds and is expressed in grams per liter, which is the unit used for regulatory limits.

What heating condition is normally used?

Most determinations use 105 ± 2 °C for one hour in a forced-ventilation oven, consistent with GB/T 1725 and ISO 3251, while ASTM D2369 specifies 110 ± 5 °C for sixty minutes. Product standards or the buyer specification always take precedence.

How does volatile content affect fire performance?

The volatile content determines the dry film thickness obtainable from each wet coat. If solids are lower than declared, the applied coating may not reach the thickness required for the specified fire rating, and the intumescent char structure formed in a fire may be inadequate.

How much sample is required for testing?

A single gravimetric determination uses about one gram, but a full report including water content, density and VOC calculation typically requires 250 to 500 milliliters of homogenized, factory-sealed sample delivered promptly to the laboratory.

How long does the determination take?

Gravimetric volatile content with water and density measurement is usually completed within three to five working days. Including gas chromatographic confirmation of individual VOCs extends the schedule to approximately seven to ten working days.